Using the tool
Enter postcode, building type, storeys, floor area and age. The tool then fills in the construction typical for that era — shown in orange.
The building fabric defaults are AS BUILT. If the house has been upgraded — new windows, loft insulation topped up, cavity filled, walls or floor insulated — you must change them, or the heat loss result shown will be too high.
Postcode i
Sets your design temperatures from the CIBSE weather zone for your area. Enter your postcode (the area letters are read — e.g. CO, M, EH). Covers all UK postcode areas.
Enter a postcode to set design temperatures.
Design percentile i
99th suits most UK homes. 99.6th is colder and more cautious — used for exposed locations, or where MCS heat-pump compliance is needed.
99th
99.6th
Building type i
Sets how many walls are exposed to outside. A mid-terrace shares two walls with neighbours (little loss there); a detached house loses through all four.
Detached
Semi
End terrace
Mid terrace
Storeys
1
2
3
Total floor area
Age band i
When it was built — sets the likely wall type and insulation era. Finer resolution for modern builds, where heat-pump retrofits happen.
Pre-1900
1900–29
1930–49
1950–75
1976–82
1983–95
1996–2006
2007–11
2012–22
2023+
Walls i
Look at the brick bond: all long faces = cavity; a pattern with short ends showing = solid. Drill-hole patches in the mortar mean the cavity's been filled. Not sure? Pick the safest (unfilled). For homes built 2007 onwards, building regs set the wall performance regardless of type — so all three options give the same result. (Photo examples coming to the guide.)
Solid brick / stone
Cavity, unfilled
Cavity, filled
Added wall insulation? i
Retrofit insulation added since the walls were built. Often you can't tell by eye — check the plans or EPC, ask the client, or look at the window reveals: external insulation deepens the outside reveal and usually means newer render; internal insulation brings the inside face forward, leaving deep internal reveals and a deeper windowsill board. A borescope confirms cavity fill. Leave as None unless you're confident. Internal and external give the same U-value in RdSAP — depth is what matters.
None
50mm
100mm
150mm
Loft insulation i
Measure the depth against a tape, using the joist depth as a guide. If it falls between options, pick the lower one — that's the safer (higher heat loss) choice. Under 50mm counts as None.
None
50mm
100mm
200mm
270mm+
Glazing
Single
Double (pre-02)
Double (modern)
Triple
Ground floor
Solid, uninsulated
Solid, insulated
Timber, uninsulated
Timber, insulated
Enter your building details above to see the estimate.